EAD 330340-00-0606: 2018工厂制造的结构锚栓CE认证/ETA认证详解-上海郜盟

工厂制造的结构锚栓ce认证标准-ETA认证
|
EAD 330340-00-0606: 2018 FACTORY MADE STRUCTURAL ANCHOR FOR ATTACHING PERSONAL FALL PROTECTION EQUIPMENT, DESIGNED TO BE PERMANENTLY AND FULLY BONDED TO A MULTI-LAYERED ROOF WATERPROOFING SYSTEM 工厂制造的结构锚栓,用于安装个人防坠落保护设备,设计为永久性且完全粘合至多层屋顶防水系统 |

This EAD specifies factory made structural anchors for attaching personal fall protection equipment,designed to be permanently fully bonded by thermal welding to a multi-layered modified bituminous roof waterproofing system provided with polyester reinforcement to a maximum roof slope of 15°, without perforating the roof waterproofing system.
上海郜盟提示本EAD规定了工厂制造的结构性锚固件,用于安装个人防坠落设备。该设计采用热焊接方式永久完全粘合于多层改性沥青屋面防水系统(配备聚酯增强层),适用于最大坡度15°的屋面,且不会穿透屋面防水系统。
NOTE 1: This EAD covers the anchors, not the roof waterproofing system to which the anchors are intended to adhere.This does not mean that the EAD does not address the assessment demonstrating that the anchor adheres to the roof waterproofing system, but means that the resulting ETA solely applies to the structural anchor, not to the structural anchor and the sheet (s) making up the roof waterproofing system.
注1:本EAD涵盖的是锚固件,而非锚固件旨在附着的屋面防水系统。这并不意味着EAD不涉及证明锚固件与屋面防水系统粘结的评估,而是指最终得出的ETA仅适用于结构锚固件,而不包括构成屋面防水系统的板材。
In accordance with Commission Implementing Decision (EU) 2015/21811, this product is not covered by a harmonised European standard.
根据欧盟委员会实施决定(EU)2015/2181,本产品不适用统一的欧洲标准。
As indicated in figure 1 the assembled structural anchor in principle consists of the following components.
如图1所示,组装式结构锚栓原则上由以下组件组成。
The lower flexible reinforced bituminous sheet of the structural anchor is intended to work as a flling layer. Its main function is to fill the space and avoid air entrapments between the structural anchor and the waterproofing sheets of the roof. This sheet does not contribute to the load bearing capacity of the anchor.
结构锚固件下方的柔性增强沥青板旨在作为填充层使用。其主要功能是填充空间,避免在结构 锚固件与屋面防水板之间形成空气滞留区。该板材不参与承担锚固件的承重能力。
The upper flexible reinforced bituminous sheet of the structural anchor contributes to the load bearing capacity of the structural anchor and shall ensure a sufficient bond with the waterproofing system on the roof in order to enable the load transfer from the anchor onto the roof waterproofing system.
结构锚的上部柔性增强沥青片材有助于提升结构锚的承载能力,并确保与屋顶防水系统充分粘结,以便将荷载从锚件传递至屋顶防水系统。
Concerning product packaging, transport, storage, maintenance, replacement and repair it is the
responsibility of the manufacturer to undertake the appropriate measures and to advise his clients on the transport, storage, maintenance, replacement and repair of the product as he considers necessary.
关于产品的包装、运输、储存、维护、更换和维修,制造商有责任采取适当措施,并就其认为必要的产品运输、储存、维护、更换和维修事宜向客户提供建议。
It is assumed that the product will be installed according to the manufacturer's instructions or (in absence of such instructions) according to the usual practice of the building professionals.
假设产品将按照制造商的说明进行安装,或(如无此类说明)按照建筑专业人士的常规做法进行安装。
For new and existing roofs this shall be done by using the declared value of the longitudinal tensile strength as specified in the product data sheet of the reinforced bituminous sheets according to EN 13707. The values of the longitudinal tensile strength for the individual polyester reinforced bituminous sheets, as used in the multi-layered modified bituminous roof waterproofing system, shall be summed together to a total maximum tensile force of the roof waterproofing system. Values for bituminous sheets, reinforced with glass fibres only, shall not be added.
对于新建和现有屋面,应按照EN13707标准中规定的增强沥青卷材产品数据表所列的纵向拉伸强度标称值进行计算。用于多层改性沥青屋面防水系统的各单层聚酯增强沥青卷材的纵向拉伸强度值应相加,得出屋面防水系统的总最大拉力。仅以玻璃纤维增强的沥青卷材数值不得计入
For existing roofs, the maximum tensile force of the multi-layered modified bituminous roof waterproofing system can also be determined by testing the maximum tensile force directly, according to EN 12311-1.
对于现有屋面,多层改性沥青屋面防水系统的最大拉力也可根据EN12311-1标准通过直接测试最大拉力来确定。
The thickness of the top layer of an existing roof waterproofing system bonded by thermal welding shall beat least 3,0 mm for non-granulated top layers and 3,5 mm for granulated top layers (total thickness) for top layers.
通过热焊接结合的现有屋顶防水系统,其顶层厚度应至少为:非颗粒状顶层3,0mm,颗粒状顶层(总厚度)3,5mm.
The thickness of the top layer of an existing roof waterproofing system bonded with hot bitumen shall be at least 2,0 mm for non-granulated top layers and 2,5 mm for granulated top layers (total thickness) for top layers.
现有屋顶防水系统采用热沥青粘结时,其顶层厚度应至少为:非颗粒状顶层2,0毫米,颗粒状顶层(总厚度)2,5毫米。
Relevant manufacturer's stipulations having influence on the performance of the product covered by this European Assessment Document shall be considered for the determination of the performance and detailed in the ETA.
相关制造商的规定若对本欧洲评估文件所涵盖产品的性能产生影响,应在确定性能时予以考虑,并在ETA中详细说明。
完成的地板或天花板覆盖物以及可能的隔音材料不属于套件的一部分。
This EAD is not applicable when
-timber treatments (preservatives, fire and flame retardants) are used, and/or
关于产品的包装、运输、储存、维护、更换和修理事宜,制造商有责任采取相应措施,并在其认为必要的情况下向客户提供有关产品运输、储存、维护、更换及修理方面的建议。
假定该产品将按照制造商的产品安装说明(MPl)进行安装,或者在无此类说明的情况下,则按照建筑专业人员的惯常做法进行安装
对于本欧洲评估文件所涵盖产品的性能判定,应考虑相关制造商的规定,这些规定会对产品性能产生影响,相关内容将在 ETA 中予以详细阐述。
Regulation (EU) No 305/2011, Directive 89/106/EEC (CPD)【旧版】
TAB机构测试+ETA认证, 由欧盟公告机构进行工厂审核后发证
|
Continuous surveillance, assessment and approval of F.P.C. 持续监视、评估和批准F.P.C. |
|
公告号机构NB1922,拥有欧盟全品类建材产品授权,上海郜盟拥有该机构直接授权,上海办公室审核员可直接代表机构进行工厂审核,大大减少工厂的差旅成本和时间成本
上海郜盟,专业CE认证服务,丰富的行业经验以及专业的工程师可帮助中国工厂快速通过合规评定,取得CE证书!!
· 如果您正在面临CE、UKCA等认证难题,欢迎联系上海郜盟获取免费预评估!
📞 咨询热线:021-34122669 021-34126062