PVC电缆出口欧盟需要满足LVD低电压指令的要求:2014/35/EU

 

PVC电缆CE认证标准

EN 50525-2-11: 2011

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V

(U0/U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation

电力电缆-额定电压450/750 V(U0/ U)及以下低压能源电缆 - 2 - 11部分:电缆通用应用程序-热塑性PVC绝缘软电缆

 

This document, which is one of a multipart series, supersedes HD 21 .1 2 S1 :1 994 + A1 :2001

and partially supersedes HD 21 .5 S3:1 994 + A1 :1 999 + A2:2001.

本文档是一个多部分系列之一,取代HD 21 .1 2 S1:1 994 + A1:2001

并部分取代HD 21 .5 S1:1 994 + A1:1 999 + A2:2001。

 

EN 50525-2-11 CE范围SCOPE

EN 50525-2-1 1 applies to thermoplastic (PVC) insulated and PVC sheathed flexible cables.

The cables are of rated voltages U 0 /U up to and including 300/500 V.

EN 50525-2-1适用于热塑性塑料(PVC)绝缘和聚氯乙烯护套软电缆。额定电压为U 0 /U 300/ 500v及以下。

The cables are intended for the connection of domestic appliances to the fixed supply.

Circular cables and flat cables are included.

这些电缆是用来连接家用电器到固定电源的。包括圆形电缆和扁平电缆。

The maximum conductor operating temperatures for the cables in this standard are 70 °C

(VV types) and 90 °C (V2V2 types).

该标准电缆导体的最高工作温度为:70℃(VV类型)和90℃(V2V2类型)。

NOTEHD 51 6 contains extensive guidance on the safe use of cables in this standard.

hd516在本标准中包含了广泛的电缆安全使用指南。

This EN 50525-2-1 1 should be read in conjunction with EN 50525-1 , which specifies general

requirements.

该EN 50525-2-11应与EN 50525-1一起阅读,后者规定了一般要求。

 

EN 50525-2-11覆盖CE电缆型号

- H03VV-F

- H03VVH2-F

- H05VV-F

- H05VVH2-F

- H03V2V2-F

- H03V2V2H2-F

- H05V2V2-F

- H05V2V2H2-F

- H05V2V2D3-F

 

 

CE认证关于PVC电缆结构、材料、装配要求

 

1 导体:Class 5 EN 60228

2 绝缘材料需符合: EN 50363-3 Insulating, sheathing and covering materials for low voltage energy cables – Part 3: PVC insulating compounds  TI 2或 TI 3  

3 装配:

-circular cables: the cores shall be twisted together;

圆电缆:芯要拧在一起

- flat cables: the cores shall be laid parallel.

扁电缆:芯应平行放置

4 护套材料需符合: EN 50363-4-1 Insulating, sheathing and covering materials for low voltage energy cables – Part 4-1: PVC sheathing compounds;TM 2或 TM 3  

注意:Strain-bearing member:承重构件应由七股钢索组成,每股直径0,25毫米。个别的线(股)应镀锌。应在应变轴承构件上覆盖一层通过挤压施加的防腐层。受拉构件的断裂载荷≥250N。

 

 

PVC电缆CE认证流程

 

 

 

PVC电缆CE Mark标识要求

每一个指定的标记,如果标记的结束与下一个相同标记的开始之间的距离不超过:

a) 550 mm如果标识在电缆的外护套上;

b) 275 mm 如果标识:

1) 在无护套电缆的绝缘上;

2) 在护套电缆的绝缘上

3) 在带护套的电缆内的带条上

 

了解更多:

电缆CE认证

低烟无卤电缆CE认证

橡胶电缆CE认证

 

郜盟国际的服务

致力于中国制造全球化服务!

专业提供欧盟CE认证美国FCC认证俄罗斯EAC认证沙特SASO认证英国UKCA认证尼日利亚SONCAP认证等国际检测认证技术服务!

PVC电缆CE认证详解

主营业务

 

MAIN BUSINESS

专业国际检测认证机构

021-34122669